Wika 762.14 Manual do Utilizador Página 5

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 4
Pressure ranges Working pressure max.
(static pressure)
Standard Option
Overpressure safety, single,
dual or alternating sides
Standard Option
0 ... 16 to 0 ... 40 mbar 2.5 6 2.5 -
0 ... 60 to 0 ...
250 mbar
6 10 2.5 6
0 ... 400 mbar 25 40 4 40
0 ... 0.6 bar 25 40 6 40
0 ... 1 bar 25 40 10 40
0 ... 1.6 bar 25 40 16 40
0 ... 2.5 to 0 ... 25 bar 25 40 25 40
WIKA Operating instructions pressure gauges Model 7 per ATEX
5
GB
2080284.06 10/2013 GB/D/F
3. Technical data and intended use
3. Technical data and intended use
Pressure limitation
Model 73x.51/31: Steady: full scale value
Fluctuating: 0.9 x full scale value
Table 1: Max. working pressure / Overpressure safety maximum in bar
Model 73x.14: Steady: full scale value
Fluctuating: 0.9 x full scale value
Overpressure safety: 40, 100, 250 or 400 bar
Process connection
In accordance with the general technical regulations for pressure gauges
(i.e. EN 837-2 „Selection and installation recommendations for pressure
gauges“).
When screwing gauges in, the force required for this must not be applied
through the case, but rather through the spanner flats (using a suitable tool)
provided for this purpose on the square shaft of standard connections.
Temperature effect
When the temperature of the measuring system deviates from the reference
temperature (+20 °C): max. ±0.5 %/10 K of full scale value
IP Ingress protection
IP 54 per EN 60 529 / IEC 60 529
(with liquid filling IP 65)