9WIKA operating instructions submersible pressure transmitter, model LH-10
14075011.01 08/2013 GB/D/F/E
GB
Output signals
Signal type Signal
Current (2-wire) 4 ... 20 mA
Current (3-wire) 0 ... 20 mA
Voltage (3-wire) DC 0 ... 5 V
DC 0 ... 10 V
DC 0.5 ... 2.5 V
Power supply
The power supply depends on the selected output signal.
4 ... 20 mA: DC 10 ... 30 V
0 ... 20 mA: DC 10 ... 30 V
DC 0 ... 5 V: DC 10 ... 30 V
DC 0 ... 10 V: DC 14 ... 30 V
DC 0.5 ... 2.5 V:
DC
5 ... 30 V (suitable for battery
operation)
Ingress protection (per IEC 60529)
IP 68
Permissible temperature ranges
Fluid
- PUR cable: -10 ... +50 °C
- FEP cable: -10 ... +85 °C
Ambient: -10 ... +50 °C
Storage: -30 ... +80 °C
Submersion depths
Submersible pressure
transmitter with FEP cable: up to 100 m
Submersible pressure
transmitter with PUR cable: up to 300 m
CE conformity
EMC directive 2004/108/EC, EN 61326 emission (group 1,
class B) and immunity (industrial application)
For special model numbers, e.g. LH-10000, please note the specications stated on the delivery note.
For further specications see WIKA data sheet PE 81.09 and the order documentation.
4. Design and function
4.1 Description
The prevailing pressure is measured at the sensor element through the deformation of a diaphragm. By supplying
power, this deformation of the diaphragm is converted into an electrical signal. The output signal from the pressure
transmitter is amplied and proportional to the prevailing pressure.
4.2 Scope of delivery
Cross-check scope of delivery with delivery note.
3.Specications/4.Designandfunction