6. Commissioning, operation
In hazardous areas, only use temperature transmitters that
are approved for those hazardous areas. The approval is
marked on the product label.
6.1 Mounting
The model T24.10 transmitters are designed to be mounted on a
measuring insert in a Form B DIN connection head. The connection
wires of the measuring insert must be approx. 40 mm long and
insulated.
Mounting example:
2476890.A1
Mounting on the measuring insert
Mount the transmitter on the circular plate of the measuring insert
using two countersunk M3 screws per ISO 2009.
Check the screw length before xing the transmitter to the measuring
insert: Insert the screw into the circular plate and verify length of 4 mm!