Wiring details
Bayonet connector, 4-pin Circular connector M12x1,
4-pin
Circular connector M12x1,
5-pin
Flying leads, 1.5 m or 3 m
4
3
1
2
3-wire U+ = A U- = D S+ = B U+ = 1 U- = 3 S+ = 4 U+ = 1 U- = 3 S+ = 4 U+ = red U- = black S+ = brown
Switching outputs SP1 = 2 SP1 = 2, SP2 = 5 SP1 = blue, SP2 = white
Wire gauge - - - 0.22 mm
2
(AWG 24)
Diameter of cable - - - 4.8 mm
Ingress protection
per IEC 60529
IP 67 IP 67 IP 67 IP 65
The ingress protection classes specied only apply while the pressure transmitter is connected with female connectors
that provide the corresponding ingress protection.
Wiring details
Sub-D HD connector, 15-pin
3-wire U+ = 7 U- = 5
U- = 12
S+ = 2
Switching outputs SP1 = 14, SP2 = 13
Wire gauge -
Diameter of cable -
Ingress protection
per IEC 60529
IP 20
The ingress protection classes specied only apply while the pressure transmitter is connected with female connectors
that provide the corresponding ingress protection.