Operating instructions/Betriebsanleitung, WUD-2x
11611057.01 GB/D 11/2013
10
Wiring details
Bayonet connector, 4-pin Circular connector M12x1,
4-pin
Circular connector M12x1,
5-pin
Flying leads, 1.5 m or 3 m
3-wire U+ = A U- = D S+ = B U+ = 1 U- = 3 S+ = 4 U+ = 1 U- = 3 S+ = 4 U+ = red U- = black S+ = brown
Switching outputs SP1 = 2 SP1 = 2, SP2 = 5 SP1 = blue, SP2 = white
Wire gauge - - - 0.22 mm
2
(AWG 24)
Diameter of cable - - - 4.8 mm
Ingress protection
per IEC 60529
IP 67 IP 67 IP 67 IP 65
The ingress protection classes specied only apply while the pressure transmitter is connected with female connectors
that provide the corresponding ingress protection.
Wiring details
Sub-D HD connector, 15-pin
3-wire U+ = 7 U- = 5
U- = 12
S+ = 2
Switching outputs SP1 = 14, SP2 = 13
Wire gauge -
Diameter of cable -
Ingress protection
per IEC 60529
IP 20
The ingress protection classes specied only apply while the pressure transmitter is connected with female connectors
that provide the corresponding ingress protection.