Wika WUD-26 Manual do Utilizador Página 17

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 44
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 16
11611057.01 GB/D 11/2013
17
Operating instructions/Betriebsanleitung, WUD-2x
Menu (programming and factory setting)
Operating mode
Long press on down key
Programming mode
Factory setting:
SP1 Value
(Min: MBA +0.5 % Max: MBE) 60 % of instrument nominal pressure
RP1 Value
(Min: MBA Max: SP1 -0.5 %) 40 % of instrument nominal pressure
SP2
1)
Value
(Min: MBA +0.5 % Max: MBE) 60 % of instrument nominal pressure
RP2
1)
Value
(Min: MBA Max: SP2 -0.5 %) 40 % of instrument nominal pressure
EF RES Yes / No
Reset to factory setting
DS1 Value
0 ... 50 s 0 s
DR1 Value
0 ... 50 s 0 s
DS2
1)
Value
0 ... 50 s 0 s
DR2
1)
Value
0 ... 50 s 0 s
OU1 PARA
OFF, ON, NO, NC NO
OU2
1)
PARA
OFF, ON, NO, NC NO
DISU Value
0.2, 0.5, 1, 5, 10, 60 seconds 0.2 s
DISO Value
(± 10 % of full scale) 0%
Legend:
MBA = Start of measuring range
MBE = End of measuring range
1) Only available for instruments with two switching outputs
END END
Operating mode
7. Initial start-up and operation
The switch returns to the operating mode, if no key is pressed within 1 minute.