GB
14096788.01 07/2014 GB/D
20 WIKA operating instructions models TR31-3, TR31-K
6.2 Electrical connection
The electrical connection is made via a circular connector.
■
M12 x 1, 4-pin circular connector
Pin Signal Description
1
L+ 10 ... 30 V
2
VQ not connected
3
L- 0 V
4 C not connected
Pt100andPt1000outputsignal 4...20mAoutputsignal
6. Commissioning, operation
■
Directly connected cable
Wire Signal Description
brown
L+ 10 ... 30 V
blue L- 0 V
Pt100andPt1000outputsignal 4...20mAoutputsignal
2-wire
red
white
white
white
white
red
red
red
red
3-wire
4-wire
brown
blue