Wika 732.15.100 Manual do Utilizador Página 4

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 68
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 3
4
11592011.04 06/2014 GB/D/F/I
GB
WIKA operating instructions dierential pressure gauge models 712.15.100, 732.15.100
1. Safety ... 3. Installation
2. General information
These operating instructions are based upon the following:
EN 837-2: Selection and installation recommendations for pressure gauges
Data sheet PM 07.29: Dierential pressure gauges models 712.15.100, 732.15.100
Data sheet PM 02.01, PM 02.02: Bourdon tube pressure gauges
3. Installation
The installation of the dierential pressure gauge should be carried out in accordance with the
installation recommendations for pressure gauges per EN 837-2 /7.
Prior to the installation of the pressure gauge, the pipes should be thoroughly cleaned
The pressure gauge should be installed and operated such as to avoid exposure to
vibration.
Mounting by means of - rigid tailpipe and/or
- 4 M8 threaded mounting holes incorporated in the body
The pressure gauges should be protected against contamination and high temperature
uctuations
The maximum permissible media/ambient temperature must not be exceeded
Fitting of the pressure connections as per the
j
and
i
symbols
j
higher pressure ⇒ bottom pressure (p
B
),
i
lower pressure ⇒ working pressure/overriding pressure (p
D
)
p
B
= p
FL
+ p
D
(with p
FL
= hydrostatic pressure of liquid = ρ g h)
1. Safety
WARNING!
Before installation, commissioning and operation, ensure that the
appropriate dierential pressure gauge has been selected in terms of
measuring range, design and specic measuring conditions.
Only work on the gauge with the voltage disconnected.
Non-observance can result in serious injury and/or damage to equipment.
Only appropriately qualied skilled personnel should work on these
instruments.
Vista de página 3
1 2 3 4 5 6 7 8 9 ... 67 68

Comentários a estes Manuais

Sem comentários