Wika LSD-30 Manual do Utilizador Página 14

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 104
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 13
14 WIKA operating instructions level switch model LSD-30
GB
11613033.01 01/2012 GB/D/F/E
3.10 Approvals, directives and certicates
CE conformity
EMC directive: 2004/108/EC, EN 61326-2-3 emission (group 1, class B) and interference immunity
(industrial application)
RoHS conformity: Yes
3.11 Electrical connections
Connections
Circular connector M12 x 1, 4-pin
Circular connector M12 x 1, 5-pin (only for version with SP1, SP2 and S
+
)
Ingress protection
IP 65 and IP 67
The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the appropriate ingress
protection.
Electrical safety
Short-circuit resistance: S
+
/ SP1 / SP2 vs. U
-
Reverse polarity protection: U
+
vs. U
-
Insulation voltage: DC 500 V
Overvoltage protection: DC 40 V
For further specications see WIKA data sheet LM 40.01 and the order documentation.