The configuration of the measuring cells differs depending on the
measuring range:
Fig. 7: Metallic measuring cell 10 mbar and 30 mbar - p
1
and p
2
process
pressures
1 Measuring element
2 Silicone diaphragm
3 Separating diaphragm
4 Filling oil
5 Integrated overvoltage arrester
Fig. 8: Metallic measuring cell from 100 mbar - p
1
and p
2
process pressures
1 Measuring element
2 Overload diaphragm/Middle diaphragm
3 Filling oil
4 Separating diaphragm
Power is supplied via the H1 Fieldbus. A two-wire cable according to
Fieldbus specification serves as carrier of both power and digital data
for multiple sensors. This cable can be operated in two versions:
l via an H1 interface card in the control system and additional power
supply
l via a Linking device with HSE (High speed Ethernet) and
additional power supply according to IEC 61158-2
Power supply and bus
communication
Differential pressure transmitter DPT10 - metal measuring diaphragm • Foundation Fieldbus 11