WIKA operating instructions models TR12, TC12 (Ex d) 19
6.2 Electrical connection
Variant 1
For the electrical specications (e.g. connection diagrams, tolerance values, etc.) please
refer to the data sheets TE 60.17 (for TR12) and TE 65.17 (for TC12).
Variant 2
For the electrical specications (e.g. connection diagrams, tolerance values, etc.) please
refer to the relevant operating instructions and/or data sheet for the built-in head-mounted
transmitter.
Variant 3
For the electrical specications (e.g. connection diagrams, tolerance values, etc.) please
refer to the relevant operating instructions and/or data sheet for the built-in Ex d eld
transmitter.
Variant 1 and 2
Junction between Ex d cable gland and connection head
Threads M20 x 1.5: tightening torques 12 Nm
Threads ½ NPT: tightening torques 30 Nm
Junction between cable and Ex d cable gland
Screw the male nut tightly into the adapter (use appropriate tools!)
During installation, take care to
Avoid distorting the cable sheath when tightening the male nut.
Avoid cutting too deep into the cable sheath.
Use suitable cable.
Be careful of the clamping zone of the cable gland.
7. Information on mounting and operation in hazardous areas
WARNING!
Non-observance of these instructions and their contents may result in the loss
of explosion protection.
The requirements of the 94/9/EC (ATEX) directive must be followed. Additionally
the specications of the respective national regulations concerning Ex usage
(e.g. EN/IEC 60079-10 and EN/IEC 60079-14) apply.