WIKA operating instructions model 54, Twin-Temp 13
8. Faults / 9. Dismounting, return, disposal
Signal interference
Stray currents caused
by electric elds or earth
loops
Use screened connecting
cables, increase in the
distance to motors and
power lines
Earth circuits Eliminate potentials, use
galvanically isolated trans-
mitter supply isolators or
transmitters
CAUTION!
If faults cannot be eliminated by means of the measures
listed above, the instrument must be shut down immedi-
ately, and it must be ensured that pressure and/or signal
are no longer present, and it must be prevented from being
inadvertently put back into service.
In this case, contact the manufacturer.
If a return is needed, follow the instructions see chapter 9.2
"Return".
9. Dismounting, return and disposal
WARNING!
Residual media in dismounted instruments can result in
a risk to persons, the environment and equipment. Take
sucient precautionary measures.
9.1 Dismounting
WARNING!
Risk of burns!
Let the instrument cool down suciently before
dismounting! During dismounting there is a risk of
dangerously hot pressure media escaping.