10 WIKA operating instructions models 53, 54, 55 (ATEX)
3. Specications
Specications
Model 53 Model 54 Model 55
Measuring element Bimetal coil
Nominal size 3", 5" 63, 80, 100, 160 63, 100, 160
Instrument version
Model A5x
Model R5x
Model S5x
Back mount (axial)
- Lower mount (radial)
Back mount, housing can rotate and swivel
Permissible ambient
temperature
-20 ... +60 °C max. -50 ... +60 °C
Working pressure
Continuous load (1 year)
Short term (max. 24 h)
Measuring range (EN 13190)
Scale range (EN 13190)
Case, ring
Stainless steel
1.4301 (304)
Stem, process connection
Stainless steel 1.4571 (316Ti)
Ingress protection
IP 65 per EN 60529 / IEC 529
IP 66, liquid-lled
For further specications see WIKA data sheet TM 53.01, TM 54.01
or TM 55.01 and order documentation.
4. Design and function
4.1 Description
The bimetal thermometers of this series are intended for installation in
pipelines, vessels, plant and machinery.
Sheath and case are made of stainless steel.
To allow tting to the process, dierent installation lengths and
process connections are available.
Through the high protection class of the thermometer (IP 65) and its
liquid damping, operation under vibration conditions is possible.