Wika HP-2 Manual do Utilizador Página 9

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 84
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 8
9
WIKA operating instructions pressure transmitter, model HP-2
11379180.03 09/2013 GB/D/F/E
GB
3.Specications
Output signals
Signal type Signal
Current (2-wire) 4 ... 20 mA
Voltage (3-wire) DC 0 ... 5 V
DC 0 ... 10 V
USB USB 2.0
Power supply
The power supply depends on the selected output signal
4 ... 20 mA: DC 10 ... 30 V
DC 0 ... 5 V: DC 10 ... 30 V
DC 0 ... 10 V: DC 14 ... 30 V
USB 2.0: DC 5 V
LoadinΩ
Current output (2-wire): ≤ (power supply - 10 V) / 0.02 A
Voltage output (3-wire): > maximum output signal / 1 mA
Ingress protection (per IEC 60529)
Angular connector DIN 175301-803 A: IP 65
Circular connector M12 x 1 (4-pin): IP 67
USB connector type A: Instrument: IP 67, connector: IP 20
Cable outlet: IP 67
The stated ingress protection only applies when plugged in using mating connectors
that have the appropriate ingress protection.
Permissible temperature ranges
Medium: 0 ... +80 °C
Ambient: -20 ... +80 °C
Storage: -40 ... +85 °C
CE conformity
EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and immunity
(industrial application)
With USB signal output and strong electromagnetic disturbances in the frequency
range 650 … 750 MHz, the accuracy can be inuenced by up to 1 %.
Pressure equipment directive 97/23/EC
RoHS conformity
Yes
For special model numbers, e.g. HP-20000, please note the specications stated on the
delivery note.
For further specications see WIKA data sheet PE 81.53 and the order documentation.
Vista de página 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 83 84

Comentários a estes Manuais

Sem comentários