Wika IPT-11 Manual do Utilizador Página 35

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 56
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 34
Diagnostics
3
Basic adjustment
Display
Diagnostics
Service
Info
3.1
Pointer
p-min.: -5.8 mbar
p-max.: 167.5 mbar
T-min.: -12.5 °C
T-max.: +85.5 °C
3.2
Sensor status
OK
3.3.1
Trend curve
Start trend curve?
Service
4
Basic adjustment
Display
Diagnostics
Service
Info
4.1
Current output
Output mode: 4-20 mA
Fail.mode: < 3.6 mA
Min. current: 3.8 mA
max. current: 20.5 mA
4.2
Simulation
Start simulation
4.3
Reset
Select reset
4.4
Language
Deutsch
4.6
HART mode
Standard
Address 0
4.7
Copy sensor data
Copy sensor data?
4.8
PIN
Enable?
4.9
Application
Level
Info
5
Basic adjustment
Display
Diagnostics
Service
Info
5.1
Sensor type
Serial number
12345678
5.2
Date of manufacture
e.g. 16. May 2008
Software version
e.g. 3.50
5.3
Last change using PC
e.g. 16. May 2008
5.4
Sensor characteristics
Display now?
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor 4 20 mA/HART 35