Wika DPT-10 Manual do Utilizador Página 84

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 96
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 83
11.2 Information on Probus PA
Instrument master le
The instrument master le (GSD) contains the characteristic data of the Probus PA instrument.
These data are, e.g. the permissible transmission rates as well as information on diagnostics values
and the format of the measured value outputted by the PA instrument.
A bitmap le is also provided for the Probus network planning tool. This le is installed automatically
when the GSD le is integrated. The bitmap le is used for symbolic indication of the PA instrument in
the conguration tool.
Ident number
Each Probus instrument gets an unambiguous ident number (ID number) from the Probus user
organisation (PNO). This ID number is also included in the name of the GSD le. For DPT10 the ID
number is 0 x 0BFB(hex) and the GSD le DF650BFB.GSD. Optionally to this manufacturer-specic
GSD le, PNO provides also a general so-called prole-specic GSD le. For DPT10 you have to use
the general GSD le PA139701.GSD. If the general GSD le is used, the sensor must be set to the
prole-specic ident number via the DTM software. By default, the sensor operates with the
manufacturer-specic ID number.
When using the pr ole-specic GSD le, the PA-OUT value as well as the temperature value are
transmitted to the PLC (see block diagram "Cyclical data trac").
Cyclical data trac
The master class 1 (e.g. PLC) cyclically reads out measured values from the sensor during operation.
The below block diagram below shows which data can be accessed by the PLC.
bar
% Lin%
Min-Max
adjustment
Linearization
PROFIBUS PA-output
Primary
Value
Secondary
Value 1
Secondary
Value 2
Target
Mode
Failure
mode
AlarmsScaling
Source for
scaling
t
i
Damping
Sensor
characteristics
PA-Out
TB
FB
Select additional cyclic
value
Sensor mounting
correction
Fig. 52: DPT10: Block diagram with AI (PA-OUT) value and Additional Cyclic Value
84 Dierential pressure transmitter DPT10 - metal measuring diaphragm Probus PA
11 Supplement
37245-EN-100120